Check the main design dimensions as shown: R - 01
Icon code |
Design size |
Tolerance |
A |
11.50 | Minimum value |
B | 17.70 | The maximum value |
C | 2.20 | Minimum value |
E | 13.30 | ± |
F | 0.90 |
±0.10 |
G | 24.40 | The maximum value |
H | 19.10 |
±0.30 |
I | 1.30 |
±0.10 |
J | 1.50 |
±0.10 |
K | Reference | |
M | 3.50 | Minimum value |
R | 0.20 | Reference |
W |
1.00 |
Reference |
Z | Reference |
● Detection tool:digital caliper or micrometer.
● Indicate the code for inspection.
● The number of outlet slots is 4×2.
● hole A is not roundness≤0.20mm,both sides of the hobbing plane of the parallelism≤0.20mm,no significant warping.
● hole hole anastomosis is not allowed to have a step,feel smooth and unimpeded.
● no residual shape or damage,color is no different normal
● finish up to▽7 or more,but allow for harmless scars and miniatures.
● Metal-free impurities or other debris,containing metal,debris products,must be waste separation.
● no melting marks,no internal pores bright spot.There are stomatal highlights(excluding melting marks)products for foreign goods.
● no flash,burr and excess material.Key parts of the burr≤0.05 mm.
● anti-pressure≥25 kg/square centimeter,no damage.
● feel a strong elasticity,and not brittle.
● hardness,wear resistance are suitable for high-speed heavy-duty rotation.
● Selection of raw materials must meet the requirements of the EU ROHS directive,and has UL yellow card certification and fixed-point supply.
● heat distortion temperature≥120 degrees Celsius,insulation resistance must be≥1000M ohm,flame retardant UL94Vo level/0.8-3.2mm.
● other structures should meet the transformer manufacturing process as the standard.