According to the design to check the main design size: R-18D insideA
|
Icon code |
Design size |
Tolerance |
|
A |
17.20 | Minimum value |
| B | 31.50 | The maximum value |
| C | 1.95 | Minimum value |
| D | 23.60 | Reference |
| E | 19.80 | Reference |
| F | 1.30 |
±0.10 |
| G | 42.90 | The maximum value |
| H | 33.00 |
±0.30 |
| I | / |
±0.10 |
| J | / |
±0.10 |
| W | 1.10 | Reference |
● Detection tool:digital caliper or micrometer.
● Indicate the code for inspection.
● the number of outlet slot 5×2,hanging hook 2.
● hole A is not roundness≤0.20mm,both sides of the hobbing plane of the parallelism≤0.20mm,no significant warping.
● hole hole anastomosis is not allowed to have a step,feel smooth and unimpeded.
● no residual shape or damage,color is no different normal
● finish up to▽7 or more,but allow for harmless scars and miniatures.
● Metal-free impurities or other debris,containing metal,debris products,must be waste separation.
● no melting marks,no internal pores bright spot.There are stomatal highlights(excluding melting marks)products for foreign goods.
● no flash,burr and excess material.Key parts of the burr≤0.05 mm.
● anti-pressure≥25 kg/square centimeter,no damage.
● feel a strong elasticity,and not brittle.
● hardness,wear resistance are suitable for high-speed heavy-duty rotation.
● Selection of raw materials must meet the requirements of the EU ROHS directive,and has UL yellow card certification and fixed-point supply.
● heat distortion temperature≥120 degrees Celsius,insulation resistance must be≥1000M ohm,flame retardant UL94Vo level/0.8-3.2mm.
● other structures should meet the transformer manufacturing process as the standard.
Check the main design dimensions as shown: R-18D outside
|
Icon code |
Design size |
Tolerance |
| K | 23.90 | ± |
| L | 31.20 | The maximum value |
| M | 2.40 | Minimum value |
| N | 26.50 | ± |
| O | 1.30 | ±0.10 |
| P | 37.20 | ± |
| Q | 33.50 | ±0.30 |
| R | / | ± |
| S | 1.40 | ± |
● Detection tool:digital caliper or micrometer.
● Mark the code according to the illustration.
● The number of outlet slots is 6 x 2.
● The irroundness of the inner hole K is less than 0.20mm,which is suitable for matching with the size of the inner shell D.
● No obvious steps are allowed at the anastomosis of the inner hole,and there is no obvious warping after the assembly of the two pieces,and the joint is≤0.20mm.
● The shape is not incomplete or damaged,allowing invalid defects at the anastomosis,and the color is normal.
● The finish should be at least 7,but harmless scars and microcosm are allowed.
● No metal impurities or other debris,products containing metal and debris must be isolated as waste products.
● No fusion marks,no internal porosity bright spots.Products with stomatal bright spots(without fusion marks)are used as equivalent foreign products.
● No flash,burr and excess material.Burrs in key parts≤0.05mm.
● Pressure resistance≥25 kg/cm2,not damaged.
● Feel strong elasticity,and not brittle.
● Selected raw materials must meet the requirements of the EU ROHS directive,and have UL yellow card certification and fixed supply.
● Thermal deformation temperature≥120 degrees Celsius,insulation resistance must be≥1000M ohms,flame retardant performance UL94Vo class/0.8-3.2mm.
● Other structures should conform to the transformer manufacturing process.